![]() ![]() ![]() The CitectSCADA system is easily scalable to meet GCWW future needs without requiring major system changes and utilizes many of the new version 6.0 features. Citect and Edison Automation will deliver software and services to upgrade all its water treatment plants and pumping facilities communicating across Bristol Babcock in-plant and remote RTUs. The project involves a top-end SCADA software replacement of a proprietary, non-supported system. ![]() "We believe Citect offers the best approach for GCWW now, and for many years into the future," explained Jay Kramer, IT Assistant Manager, GCWW. The GCWW Selection Committee chose Citect over several competitors citing its CitectSCADA V6 product offers the most cost-effective solution that best matches the project requirements. GCWW is one of many water/ wastewater treatment facilities that have recently selected a Citect solution as the number of companies throughout North America standardizing on CitectSCADA continues to increase. Again we or even customers can not justify this scenario to their authorities.US$1 Million Contract to Upgrade Municipal Water SCADA SystemĪlpharetta, GA Citect, a global business improvement solutions provider, and its Platinum Integration Partner, Edison Automation have been awarded a contract exceeding US$1 million with the Greater Cincinnati Water Works (GCWW) to upgrade its water treatment plants. That means my Citect Trend will show a graph of the last one week where the device itself is not working. So Citect event type trends will show graphs between 25 to 30. New device has the first reading 30 transferred to Citect. Now after one week customers procure a new device and replace the faulty device and communication will be established with Citect. Now one more example is that my slave device became faulty due to some reason and it has the last value 25 transferred to Citect. If my slave deice power fails and it took one hour to get powered up then Citect Event type trend will show graph for that duration when Device itself is powered of. We can not justify this to our customers.Ģ. When the Slave device is not in communication with Citect Scada ,Citect is showing graphs in trend screen. ![]() *But the major two disadvantages which we have observed is ġ. To use this feature we configure Event Type trends in Citect Scada so that DNPr slave device can back fill data into Citect Trend. We are using the back-filling feature of DNPr driver with Citect Scada. *Form last 3 to 4 years we have been selling and proposing Citect Scada with DNPr driver in Pharmaceutical Companies as a 21CFR compiled Solution. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |